Lucity Views

The Lucity Views tools create a snapshot view of Inspection, Models, Work, and Request data in the Lucity System. The inspection views are based on the most recent inspection done on each type of asset. The model views allow users to see the most recent results of each model run. Each of these creates a temporary feature class to display the information. These temporary feature classes can be exported and saved for further use. The Work and Request views require the additional setup of the Lucity Live data repository and service.

Note: For a view to work the feature class it is based on must be in the map. For example the Sewer Pipes must be in the map for the PACP Inspection Summary view to work.

How To Use the Lucity Views

How To Recreate a View

Description of each view

Tool

Operation

Sewer

View Manhole Inspection Results

Graphically displays the latest manhole inspection information as another instance of the sewer structure feature class. This instance will have the latest structure inspection information for each structure joined to the attribute table. The symbology for the layer is based on the total structural number (MH_SUM_STR) of the inspection. Manholes with a lower structural number will appear yellow; manholes with a higher structural number will appear red.

View TV Inspection Summary

Graphically displays the latest TV inspection information as another instance of the sewer pipe feature class. This instance will have the latest TV inspection information for each pipe joined to the attribute table. The symbology for the layer is based on the total structural number (TL_STR_TOT) of the inspection. Pipes with a lower structural number will appear yellow; pipes with a higher structural number will appear red.

View PACP Inspection Summary

Graphically displays the latest PACP inspection information as another instance of the sewer pipe feature class. This instance will have the latest PACP inspection information for each pipe joined to the attribute table. The symbology for the layer is based on the total pipe rating (PA_PRT) of the inspection. Pipes with a lower structural number will appear yellow; pipes with a higher structural number will appear red.

View Lamping Inspection Results

Graphically displays the latest lamping inspection results as two additional instances of the sewer pipe feature class. One instance will be for lamping inspections from the downstream structure, the other for inspections from the upstream structure. These added layers will have the latest lamping inspection information for each pipe joined to the attribute table. The symbology for the layers is based on the total structural number (LP_TOT_STR) of the inspection. Pipes with a lower structural number will appear yellow; pipes with a higher structural number will appear red.

View Smoke Inspection Summary

Graphically displays the latest smoke test inspection information as another instance of the sewer pipe feature class. This instance will have the latest smoke test inspection information for each pipe joined to the attribute table. The symbology for the layer is based on the result text (SM_RSLT_TY) of the inspection.

View Sewer Rehab Results

Graphically displays the sewer rehab results as another instance of the sewer pipe feature class. This instance will have the latest Pipe Analysis Details for each pipe joined in the attribute table.

Storm

View Structure Inspection Results

Graphically displays the latest structure inspection information as another instance of the storm structure feature class. This instance will have the latest structure inspection information for each structure joined to the attribute table. The symbology for the layer is based on the total structural number (SI_STR_TOT) of the inspection. Structures with a lower structural number will appear yellow; structures with a higher structural number will appear red.

View TV Inspection Summary

Graphically displays the latest TV inspection information as another instance of the storm conduit feature class. This instance will have the latest TV inspection information for each pipe joined to the attribute table. The symbology for the layer is based on the total structural number (CI_TOTSTRC) of the inspection. Pipes with a lower structural number will appear yellow; pipes with a higher structural number will appear red.

View Storm Sampling Results

Graphically displays the latest storm sampling result information as another instance of the storm structure feature class. This instance will have the latest storm sampling information for each structure joined to the attribute table. The symbology for the layer is based on the total PH count (SS_PH_D, SS_PH_U, SS_PH_A) of the inspection. The results will create a group layer with three feature classes, representing samples that were performed upstream from the structure, downstream from the structure, and at the structure.

Street

View Street PCI Data

Graphically displays the current PCI data as another instance of the street subsegment feature class. This instance will have the latest field inspection information for each subsegment joined to the attribute table. The symbology for the layer is based on the current PCI number (FD_CUR_PCI) of the inspection. Subsegments with a lower PCI will appear yellow; subsegments with a higher PCI will appear red.

View Street Modeling Results

Graphically displays the modeling results as another instance of the street subsegment feature class. This instance will have the selected model result details for each subsegment joined to the attribute table. The symbology for this layer is based on the Rehab Text of the model result.

Water

View Hydrant Flow Test Results

Graphically displays the latest hydrant flow test results as another instance of the hydrant feature class. This instance will have the latest hydrant flow test information for the hydrant joined to the attribute table. The symbology for the layer is based on the flow at 20psi (HT_Q20) of the hydrant. Hydrants with a lower flow at 20psi will appear yellow; hydrants with a higher flow at 20psi will appear red.

View Test Dates for Backflow Devices

Graphically displays the next backflow device test dates as another instance of the backflow device feature class. This instance will have some inventory data for the backflow device joined to the attribute table. The symbology for the layer is based on the next test date (BF_NTST_DT) of the backflow device. Devices with an earlier next test date will appear yellow; devices with a later next test date will appear red.

View Meter Device and AMR Info

Graphically displays the water meter locations with all of the fields from the Water Meter Device, and AMR reader modules. These fields are populated with information from the device and reader that are attached to the Water Meter Location.

Work

View Live Work Request Layers

Graphically displays the locations of current work requests that are posted to the Live Data Repository. This view requires that a live data repository be setup in a geodatabase and that the live data update tool be running on a machine.

View Live Work Order Layers

Graphically displays the locations of current work orders that are posted to the Live Data Repository. This view requires that a live data repository be setup in a geodatabase and that the live data update tool be running on a machine.

See Also

Analyst Tools

Lucity Module Tool

Filter Viewer

Subset Manager

Work Frequency

Create Lucity Work Layers

Work Request Location

Work Order Locations

Master Project Locations

PM Work Locations

Profile Tool

View TV Observations

Trace Solver

Update Sign Regulations

Customer Search

Find Feature

Lucity Field Links