The Lamping tab provides an overview of the most recent lamping inspections and provides a historical listing of all lamping inspections for the sewer pipe. The records in this grid come from the Line Lamping Inspection module. At the top of the screen, there are two sections: one that displays data from the most recent upstream to downstream inspection, and one that displays data from the latest downstream to upstream inspection.
US/DS Lamping Date |
The date of the most recent line lamping inspection. |
US/DS Velocity |
The flow speed in the pipe in feet per second. |
US/DS Flow Depth |
The total depth of liquid and obstructions, in inches, measured to the nearest quarter inch. |
US/DS Depo Depth |
The approximate depth of the obstructions flowing/settling in the pipe (in inches). |
Total Remaining (Structural, Flow, Cleaning) |
The sum of the assigned numbers (structure, cleaning, flow) from all observation records in the Line Lamping Inspection module. |
Note: The Structural, Flow, and Cleaning fields are calculated based on the quantitative ratings recorded in the Inspection Setup module.
More information on how the Structural, Flow and Cleaning fields are calculated
The Lamping tab also contains a grid that lists all of the line lamping inspections for a particular pipe.
A sample of the grid appears below. Sort records in the grid by clicking on the headings. An up or down arrow (highlighted in orange below) indicates whether data appear in ascending or descending order.
How To Add a Lamping Inspection
Note: For more information about Line Lamping Inspections go here.