The Attribute 1 tab stores information about the location of the service connection and its relationship to the rest of the sewer network. This tab contains several fields that link this record to other modules.
Field |
Special Function |
Connected To |
Specifies the item to which the service connection is attached. This field controls the functionality of certain other fields. If 1 - Sewer Pipe is selected, the Alt Pipe ID field is available; however, the Network Structure field is not. If 2 - Network Structure is selected, the Alt Pipe ID field is unavailable and the Network Structure field is activated. If nothing is selected, or another option is selected, both fields are available. Note: Selecting both a pipe and structure can cause some auto-populated fields to have incorrect data. |
Alt Pipe ID |
Specifies the sewer pipe with which the service connection is associated. Click on the field caption or click in the field and push F9 for a list of pipes to select from. |
Network Structure |
Specifies the sewer structure with which the service connection is associated. Click on field caption or click in the field and push F9 for a list of structures to select from. |
Pipe Data Fields
Pipe Data Fields
|
Attributes of the related pipe that are automatically filled out when the Alt Pipe ID is selected. |
Structure Data Fields
US/DS Structure No. Address/General Location Loc. Depth |
The fields above are completed automatically when the Alt Pipe ID or the Network Structure fields are filled out. If the Alt Pipe ID is filled out, the pipe's upstream and downstream structures are populated. The other fields are filled out with the corresponding information from the US and DS structure records. If the Network Structure field is filled out, the US Structure No. field is populated with the structure number and its related fields display the corresponding information from the Structure record. |
Service Lateral Location
Service Structure |
Specifies the service lateral associated with the service connection. Click on the field caption or click in the field and push F9 for a list of laterals to select from. |
Property ID Tag |
Links the service connection to the Customer Address module. Click on the caption or click in the field and push F9 for a list of property IDs/addresses to select from. More information about the Customer Address module |
Address |
Displays the address of the lateral. This field is automatically completed when the Property ID Tag is filled out. |
Flow Basin |
Displays the Flow Basin that the Service Connection is part of. This field is automatically completed when the Alt Pipe ID or Network Structure field is filled out. |