To add an observation record, complete the following steps:

Note: The Defect Start and Defect End fields have a special function. These fields can be used if you have a problem that extends through a long stretch of pipe. The data for the starting and ending points will be housed in separate records (one for each point). By including a unique identifying code in the Defect Start field and matching that code in the Defect End field of a separate record, the system will calculate values in the Summary/Custom tab of the defect ending record. There should only be one record with an ending defect that matches a starting defect. Additionally, to ensure accurate calculations, the footage in the ending defect record should be greater than that in the starting defect record.
Note: The following fields must be populated for the system to calculate the read-only fields in the Summary/Custom tab and the Summary fields at the bottom of the Observations grid: Defect field, Observed (gpm) field, and the % I/I Removed field (in the Summary/Custom tab).
to save the observation.
to exit Add Mode.