Struct Structural

The Structure (Struct) Structural tab features three different factor types: Matrix Factor, Item Type Factor, and Defect Type Factor. The structural number assigned to each manhole defect has both a severity and a density. These factors are used to determine the overall structural number (found in the TV Inspections module under the Summary tab).

The following equation is used to determine the structural number:

Structural Number = Matrix Factor * Defect Type Factor * Item Type Factor

For example, if the wall was assigned a Broken/Missing Severity of 2 and a Density of 3, then the Structural Number assigned to the defect is:

Structural Number = 3(Matrix Factor)*2(Defect Type Factor)*2(Item Type Factor)=12

Note: Although these fields are all pre-defined, you can edit them by clicking edit on the module toolbar.

See Also

Inspection Setup

Inspection Setup Header Data

TV and Lamp Infiltration

TV and Lamp Structure

TV and Lamp Clean

Structure (Struct) Flow

Structure (Struct) Cover

Smk/Dye/Bldg

Building (Bldg) Sumps