This tab contains a grid displaying all sewer pipe connections to the structure being inspected.
A sample of the grid appears below. Sort records in the grid by clicking on the headings. An up or down arrow (highlighted in orange below) will appear signifying ascending or descending order.
How To Add a Connection
Connection Fields
Field |
Function |
Pipe Number |
The number of the pipe during the inspection. Meaning, this pipe was #1, #2, #3, etc... |
Asset ID |
The Common ID of the pipe. |
Clock Position |
This field is used to mark which direction the pipe enters the structure from (like the face of a clock 1 o'clock, 4 o'clock). |
Rim to Invert |
Indicates the distance from the Rim to the Invert of the Pipe's Upstream Manhole |
Direction |
Mark whether the pipe flows into or out of the structure. |
Material |
The material the pipe is made of. |
Shape |
The shape of the pipe. |
Diameter 1 |
The how wide the mouth of the pipe is. |
Diameter 2 |
This is a second field to measure how wide the mouth of the pipe is if it isn't a circle. |
Pipe Condition |
General condition of the pipe. |
Seal Condition |
General condition of the pipe/structure seal. |
Special Condition |
A user-defined field to keep track of the general condition of another aspect of the pipe/structure connection. |