The Sewer Pipe Inventory Check Report tool allows you to create a custom report featuring the overall condition of the pipes in the Pipe Inventory module. It allows you to find errors in your pipe network that would otherwise be difficult to locate.
Note: The permissions for this tool are controlled by the permissions for the Sewer Pipe Inventory module. If the user has permissions to view the Sewer Pipe Inventory module he or she can view these reports.
To access the Sewer Pipe Inventory Check Report, select Sewer > System Tools > Pipe Inventory Check Report
and the following window will appear:
Below is a list of the criteria for the Pipe Inventory Check Report. Some of the options are self-explanatory, others are described below.
Criteria |
Definition |
End Pipe Checkbox |
The End Pipe checkbox, if marked, locates any end pipes. End pipes are those with no pipes downstream of them. While many end pipes are outlets to treatment stations, some may represent gaps in the pipe network or may have been entered incorrectly (i.e. flowing in the wrong direction). |
Negative Drop Manholes |
This criteria searches for all manholes where the upstream pipe has a lower invert elevation than the downstream pipe. You specify the invert elevation level in the field below the checkbox. |
Excessive Drop Manholes |
This criteria searches for all manholes where an upstream pipe has a higher invert elevation than the downstream pipe. You specify the invert elevation in the field below the checkbox. |
Missing Sewer Inventory Data |
This criteria locates pipes that are missing the diameter, length, slope, rim, or invert data. |