Pump Curve Tab

The Pump Curve tab allows you to enter data regarding the pump curve tests.  Two tables are provided to record testing results for Low Speed and High Speed values. You can also indicate the low speed and high speed shut off heads. These fields are described in the table below:

Field Name

Use/Purpose

Shut Off Head L & H

The head against which the pump produces no flow.

Low H 1-6 (ft)

Pressure Head values for the pump at the low (or normal, if not variable) speed. The heads correlate with the corresponding flows (i.e. H1-Q1, H2-Q2).

High H 1-6 (ft)

Pressure Head values for the pump at high speed. The heads correlate with the corresponding flows.

Low Q 1-6 (gpm)

The pump flow rate, in gallons per minute, at the low (or normal if not variable) speed.

High Q 1-6 (gpm)

The pump flow rate, in gallons per minute, at the high speed.

See Also

Equipment Inspections

Equipment Inspections Header Data

General Condition Tab

Pump Condition Tab

Custom and Comments