Total Column

Rating

How the Rating is Obtained by the System

Structural Number Total

The system adds up the structural defects on the pipe using the matrix in the Inspection Setup module.

Flow Number Total

The system adds up the I/I (infiltration/inflow) defects on the pipe.

Cleaning Number Total

The system adds up the cleaning defects (e.g. grease, debris) on the pipe.

Remember: These numbers are not percentages; therefore, the numbers may be over 100 or even over 1000 depending on the pipe's defects (the worse the defects are, the higher the numbers will be).

See Also

Quantitative Ratings

Remaining Column

Ratings Column

Analyzing Ratings (Running Reports)

Modifying Ratings