Split Process within the Desktop Application
The following is an overview of the split process within the desktop:
- Create a new sewer structure (if not using an existing structure)
- Create two new sewer pipe records in the desktop.
- Copy attributes to new pipe records
- Associate documents to new pipe records (if not archiving)
- Update Address associations(CMADDR)
- Update Basin (SWBASINOUT)
- Update Flow Isolation (SWISONET)
- Update Observation Manholes (SWOBSMAN)
- Update Service Lateral Connections (SWSERV)
- Update pipe curve (SWCURVE)
- If Associate Inspections option is checked:
- Update Smoke tests and observations
- Update Lamp tests and observations
- Update TV inspection and observations
- Update PACP inspection and observations
- Update Construction records (if option was checked)
- Update Sewer Overflows (if option was checked)
- Update Sewer Rehab records (if option was checked)
- Update new upstream sewer pipe elevations
- Upstream elevation data is populated from the pre-split pipe's upstream elevation data
- Downstream elevation data is not calculated.
- Update new downstream sewer pipe elevations
- Upstream elevation data is not calculated
- Downstream elevation data is populated from the pre-split pipe's downstream elevation data
- Update Work Requests (if option was checked)
- Update Work Orders (if option was checked)
- Asset/Task associations are carried over to the merged pipe
- Any previous asset costs AS_WOCOST and AS_UNASGNCOST are only associated to one of the pipes
- Update PM/Work Template records (if option was checked)
- Update Master Project records (if option was checked)
- Archive or delete pre-split pipe (based upon archive option)