The Merge Sewer Pipe tool will merge two sewer pipes in the map and in the Lucity database. This too must be used instead of the ESRI merge tool. The tool also offers the ability to delete the associated sewer structure from the map and the Lucity database.
Note: The Sewer Merge Tool is only enabled if all of the following conditions are met: (1) There are two features selected in the map (2) The features selected are linear (3) The features are snapped together at one end
How To
Merge two features in the map
Existing From Pipe
: This is read-only information about the pre-merged from pipe.Existing Split Feature
: This is the existing sewer structure information and lists the various merge options for the structure.Existing To Pipe
: This is read-only information about the pre-merged to pipe.New Alt ID
(Optional): Users can manually enter a new Alt Pipe ID, use a Lucity auto number (this option is only enabled if there is an Alt Pipe ID field in the feature class that is configured to use a number generator), use the end point IDs or use the Alt Pipe ID from the longer pipe.New Pipe Length
: This option is only enabled if the tool calculates a difference between the GIS and Lucity pipe lengths. Users can choose to set the Lucity length to be equal to the GIS length or use the Lucity calculated length.New Pipe Attributes-Copy from
: Choose to copy over the attributes from the pre-merged from pipe, pre-merged to pipe, or the longer pipe.Archive
: (Optional) Select this option maintain a record in the desktop pipe inventory module for both the pre-merged pipes. The pre-merged pipes will not be deleted from the desktop inventory module if this option is selected.The pipe status will be updated to the status selected from the list.
The ability to create requests, work orders and PM/Work Template records against the pre-split pipes is now disabled. This is done by the tool updating the NT_NOWORK field.
The show in map is disabled for the pipe.
Advanced Settings
: This allows users to override the default settings that control what associations should be updated with the use of this tool. The following boxes are checked by default:Inspections
Overflows
Requests
Work Orders
PM/Work Templates
PM/Work Templates
6. After making all the necessary selections, click OK.
7. The following message will appear when the process is finished.