General
Integration w/ Facility
|
Activates the Alt. Building field for the listed Water assets, allowing users to link Water assets to Buildings in Lucity's Facility program. Through this integration, any Equipment that is associated with a linked Building appears in the Other Equipment grid on the Water asset record. Note: This option must be enabled to implement the Integration w/ Equipment. |
Integration w/ Equipment
|
Enables users to link records from the Equipment module to the listed Water assets. Note: This integration requires that the Integration w/ Facility option be enabled. |
Populate Service Tap ID w/ Acct No. and Tap No.
|
Directs Lucity to auto-populate the Service Tap ID for new Service Tap records using data from the Account Number and Tap Number fields. For example, when this option is enabled, if a user enters 444 as the Account Number and 2 for the Tap Number, the system would automatically set the Service Tap ID to be 444-2. Note: When this option is enabled, the Account Number and Tap Number fields on Service Tap records are required. |
Force Uniqueness for Address and Tap No for Service Tap Record
|
Prohibits users from saving a Service Tap inventory record if the Address and Tap Number entered are not unique. |
Update Main Break with Pipe Inventory Record Info
|
Directs Lucity to carry over Pipe attribute data when the user selects a Pipe Number in the Mainbreaks module. The attributes include the pipe's Surface Type, Pipe Depth, Diameter, Material, Map Number, Alt Map Number, Pressure Zone, and System. |
The following options dictate what happens when a user creates a Work Order from a Flushing Route.
In Flushing Route, Copy Hydrants to Work Orders with Tool Flushing Route module |
Directs the system to automatically add Hydrants on the Flushing Route as assets to Work Orders created using the Create Work Order or Create Flushing History and WO tools. |
In Flushing Route, Copy Valves to Work Orders with Tool Flushing Route module |
Directs the system to automatically add Valves on the Flushing Route as assets to Work Orders created using the Create Work Order or Create Flushing History and WO tools. |
In Flushing Route, Copy Pipes to Work Orders with Tool Flushing Route module |
Directs the system to automatically add Pipes on the Flushing Route as assets to Work Orders created using the Create Work Order or Create Flushing History and WO tools. |
Backflow
BFP Next Test Date Frequency
|
Enables an administrator to set a default numeric value for the Next Test Date Frequency field in the Backflow Inventory module, thereby assigning a standard number of Test Frequency Units (hours, days, weeks, months or years, see explanation below) between tests. |
BFP Next Test Date Frequency Units
|
Enables an administrator to set the default unit for the Next Test Date Frequency Units field in the Backflow Inventory module. This is the period of time (hours, days, weeks, months or years ) that the BFP Next Test Date Frequency number references. |
BFP Next Rebuild Date Frequency
|
Enables an administrator to set a default numeric value for the Next Rebuild Date Frequency field in the Backflow Inventory module, thereby prescribing a standard number of Rebuild Date Frequency Units (hours, days, weeks, months or years, see explanation below) before the next rebuild occurs. |
BFP Next Rebuild Date Frequency Units
|
Enables an administrator to set the default unit for the Next Rebuild Date Frequency Units field in the Backflow Inventory module. This is the period of time (hours, days, weeks, months or years ) that the BFP Next Rebuild Date Frequency number references. |
Use Testing Date to Recalculate Next Test/Rebuild Date
|
Directs Lucity to auto-populate the Next Test/Rebuild Date with the Date of the most recent Backflow Test. If this option is set to No, Lucity uses the Last Test Date and Last Rebuild Date to determine when each backflow test and rebuild is due, regardless of when the equipment was last inspected or rebuilt (as recorded in the Backflow Tests module). |
BF Tests - Validate Company Licenses and Test Kits
|
Backflow Tests Directs Lucity to verify whether the Company listed on a new Backflow Test record has a valid License and valid (unexpired) Test Kit as criteria for saving the record. Backflow Testing Companies Directs Lucity to verify whether both the Initial Tester and Final Tester are linked to a valid Company as criteria for saving the record. A Company is considered to be valid if it has at least one active license. Note: Lucity recommends that agencies enable this option. |
BFP Tester Inactive Date Frequency BFP Tester Inactive Date Frequency Units
|
Directs Lucity to calculate the Date Inactive for a Tester based on the value the user entered in the Date Active field. This calculation is based on the numeric value specified in the BFP Tester Inactive Date Frequency option and the time duration specified in the BFP Tester Inactive Date Frequency Units option. For example, if a Tester's active status should end 3 years from the Date Active, the user would enter a '3' for the BFP Tester Inactive Date Frequency option and enter a 'Years' for the BFP Tester Inactive Date Frequency Units option. |