Storm Options

General

Allow Multiple Inspection Records per Unique Structure

This option allows agencies to keep track of multiple inspections for each storm structure, which provides a historical look at that asset. If this option is set to No there can only be one inspection record per storm structure. In this case to create a new inspection record for a structure, users must either delete the old inspection, or edit the old one and update it with new inspection details and results.

Allow Multiple Inspection Records per Unique Conduit

This option allows agencies to keep track of multiple TV Inspections for each storm conduit, which provides a historical look at that asset. If this option is set to No there can only be one TV inspection record per storm conduit. In this case to create a new inspection record for a conduit, users must either delete the old inspection, or edit the old one and update it with new inspection details and results.

Allow Multiple Inspection Records per Unique Detention Basin

This option allows agencies to keep track of multiple Lamping Inspections for each storm conduit, which provides a historical look at that asset. If this option is set to No there can only be one Lamping inspection record per storm conduit. In this case to create a new inspection record for a conduit, users must either delete the old inspection, or edit the old one and update it with new inspection details and results.

Allow Multiple Inspection Records per Unique Pump Station

This option allows agencies to keep track of multiple inspections for each storm pump station, which provides a historical look at that asset. If this option is set to No there can only be one inspection record per storm pump station. In this case to create a new inspection record for a pump station, users must either delete the old inspection, or edit the old one and update it with new inspection details and results.

Allow Multiple Inspection Records per Unique Pump

This option allows agencies to keep track of multiple inspections for each storm pump, which provides a historical look at that asset. If this option is set to No there can only be one inspection record per storm pump. In this case to create a new inspection record for a pump, users must either delete the old inspection, or edit the old one and update it with new inspection details and results.

Allow Structure Inspection to Create New Structure Inventory Record

Enabling this option allows users to create an inspection record for a storm structure that isn't in the storm structure inventory. When the inspection record is saved the structure will be added to the structure inventory.

Note: This option does not take user permissions into account (i.e. a user may not have permission to add inventory records, but this option will allow them to do so).

Allow Conduit Inspection to Create New Structure Inventory Record

Enabling this option allows users to create an inspection record for a storm conduit with a storm structure that isn't in the storm structure inventory. When the conduit inspection record is saved the structure will be added to the structure inventory.

Note: This option does not take user permissions into account (i.e. a user may not have permission to add inventory records, but this option will allow them to do so).

Allow Conduit Inspection to Create New Conduit Inventory Record

Enabling this option allows users to create an inspection record for a storm conduit that isn't in the storm conduit inventory. When the inspection record is saved the conduit will be added to the conduit inventory.

Note: This option does not take user permissions into account (i.e. a user may not have permission to add inventory records, but this option will allow them to do so).

Default Length for Continuous Defect Calculation

Specify a default length for continuous conduit defects in this field. If a continuous defect is added to a conduit inspection but no length is specified, the default length specified here will be used to calculate the conduit condition.

Use Pipe Section Length when Available for Continuous Defect Calculation

Set this option to Yes to use the conduit section length (Found in the Conduit Inventory, or the Conduit Inspection > Conduits Information tab) to calculate conduit condition where a continuous defect was noted.

Note: This option supersedes the value in the Default Length... option.

Integration with Facility

This enables the integration between the Lucity Facility program, and Lucity Storm program. This allows agencies to link Storm Pump Stations to Buildings.

This enables the Alt Building No field in the Storm Pump Station Inventory.

Integration with Equipment

This enables the integration between the Lucity Equipment program and Lucity Storm program. This allows agencies to link Equipment to Storm Pump Stations and Storm Pumps.

This enables the Other Equipment tab in the Pump Station Inventory, and the Equipment tab in the Pump Inventory.

See Also

Options

General Options

Park Options

Sewer Options

Street Options

Water Options

Work Options