The Pump Curve tab allows you to document the pump elevations and indicate whether this is a variable speed pump. You can also document the Shut-off heads and Low H, Low Q, High H, and High Q. These fields and their uses are described below. All fields under this attribute tab are optional.
| Field Name | Definition | 
| Pump On Elev Pump Off Elev Pump Alarm Elev | These read-only fields are carried over from the Pump Slot record in which this pump is installed. If these fields are blank in the slot location, they will remain blank here. | 
| Low Speed (rpm) | This is the low speed in rotations per minute at which the pump operates. | 
| High Speed (rpm) | This is the high speed in rotations per minute at which the pump operates. | 
| Shutoff Head (l & H) | The head against which the pump produces no flow. | 
| Low H 1-6 | Head points for the pump at low (or normal if not variable) speed. | 
| Low Q 1-6 | Discharge points for the pump at low (or normal if not variable) speed. | 
| High H 1-6 | Head points for the pump at high speed. | 
| High Q 1-6 | Discharge points for the pump at high speed. |