The Measure of Flow Difference field (highlighted in green below) is based on the difference between the US/DS measured flow and the calculated flow (highlighted in blue).

These highlighted fields are described in the table below:
| Field Name | Description | 
| US Meas Flo | The upstream manhole flow measured by the flow measuring device, in gallons per day. | 
| DS Meas Flo | The downstream manhole flow measured by the flow measuring device, in gallons per day. | 
| US Calc Flow | The flow calculated from the depth measurement using the Mannings equation in gallons per day. | 
| DS Calc Flow | The downstream manhole calculated flow minus the upstream manhole calculated flow in gallons per day. | 
| Meas Flo Diff (gpd) | The downstream manhole measured flow minus the upstream manhole measured flow in gallons per day. |